Antarctica Nitrogen Open Head Cryotherapy Chamber
- Free USA Shipping On Many Items
- Full Warranty
- Secure Checkout
- Authorized Dealer
The CryoStar Antarctica (Nitrogen) is a whole-body, head-inside cryotherapy chamber designed for controlled cold-air exposure using a nitrogen heat-exchange system and staged operating modes. It’s built for wellness centers, recovery studios, sports performance facilities, and luxury spas that want a repeatable operator workflow, a premium client experience, and clear throughput benchmarks. Content below is condensed from manufacturer documentation and formatted to MLHS standards.
Signature Features
- Controlled Chamber Cooling: Staged programs including pre-freezing, cool-down, treatment, and drying modes.
- Modular Architecture: Three primary modules (chamber, door, machinery room) designed for serviceability.
- Touchscreen Interface: Operator menus for main run, sub-cooling, drying, and settings.
- Full Drying Cycle: Dedicated drying program between sessions to reduce frost/ice buildup.
- Emergency STOP: Quick shutoff logic for operational safety.
- Monitoring & Sensors: Chamber and exhaust temperature sensors + ambient/room condition settings.
- Flexible Protocols: Beginner, intermediate, and advanced programs with adjustable time/temperature.
Specifications
| Specification | Detail |
|---|---|
| Overall Dimensions (L × W × H) | ≈ 90.24″ × 73.62″ × 46.06″ (≈ 2292 × 1870 × 1170 mm) |
| Weight / Max Load (module spec) | ≈ 860 lb / 1,102 lb (≈ 390 kg / 500 kg) |
| Typical Nitrogen Use (10–20 sessions/day) | ≈ 15 L per session (≈ 4.0 gal) |
| Typical Nitrogen Use (>20 sessions/day) | ≈ 14 L per session (≈ 3.7 gal) |
| Power Supply | 230 V / 50 Hz standard (110 V / 60 Hz variant available) |
| Recommended Room Conditions | Humidity < 40% and ambient < 72°F (ambient < 22°C) for optimal operation |
| Safety & Operational Rules | Dry skin, remove jewelry, single user per session, trained supervision required |
| Intended Use | General wellness, recovery, and athletic performance (not a medical device) |
What’s Included
- CryoStar Antarctica cryochamber (chamber + door + machinery modules)
- Operator touchscreen control panel
- Emergency STOP integrated safety system
- Owner’s manual + operating/safety documentation
- Crated freight delivery (scheduled appointment; curbside)
Installation
Warranty Coverage
- Base Coverage – 1 Year on components (unless otherwise specified)
- Extended warranty/service plans available by quote
Warranty terms may vary by configuration and service location; final certificate is provided at sale.
How This Can Benefit Your Business
- Premium add-on service: Cryotherapy can be positioned as a time-efficient recovery session that complements massage, sauna, red light, and bodywork offerings.
- Higher visit frequency: Short session times (often 1–3 minutes) support repeat visits and easy scheduling throughout the day.
- Membership and package friendly: Works well for multi-session packs, monthly memberships, and recovery bundles (e.g., cold + massage + sauna).
- Client experience upgrade: A modern chamber with guided modes and operator workflow helps standardize sessions and training.
- Operational planning: Built-in benchmarks for nitrogen consumption help forecast supply needs for your expected daily volume.
Note: Position messaging around general wellness and comfort. Avoid medical claims and follow local regulations and manufacturer protocols.
Why Choose CryoStar Antarctica?
- Documented, repeatable operating modes (pre-freezing, sub-cooling, treatment, drying)
- High-throughput capability with clear nitrogen-consumption planning benchmarks
- Safety-first control logic with emergency stop and practical operating rules
- Integrated temperature monitoring for operator feedback
- Commercial, modular design for installation and maintenance access
Compare at a Glance
| Item | CryoStar Antarctica (Nitrogen) |
|---|---|
| Module Layout | Chamber + Door + Machinery modules |
| Nitrogen Consumption (10–20/day) | ≈ 15 L per session (≈ 4.0 gal) |
| Nitrogen Consumption (>20/day) | ≈ 14 L per session (≈ 3.7 gal) |
| Power Supply | 230 V / 50 Hz (110 V / 60 Hz optional) |
| Ambient Requirements | Humidity < 40%, ambient < 72°F (ambient < 22°C) |
| Safety Rules | Dry skin, no jewelry, single user, operator supervision |
Site Prep & Installation
- Professional Install Required: Installation and commissioning must be completed by a Cryonic Wellness Technology Factory professional (separate charge). Contact us for a quote.
- Electrical: Provide certified wiring matching the 230 V (50 Hz) standard or 110 V (60 Hz) variant; dedicated circuit and protective devices.
- Nitrogen Supply & Hose Routing: Allocate space for the Dewar/tank (not included), route the hose safely, and follow local code + supplier guidance.
- Ventilation & O2 Monitoring: Provide room ventilation and an oxygen sensor/alarm per best practices for LN₂ environments.
- Environment: Keep humidity under 40% and ambient under ~72°F to reduce condensation and support performance.
- Clearances: Confirm doorway widths, turns, module assembly space, door swing, and service access per installation drawings.
- Staff Training: Operate under trained supervision and follow manufacturer protocols at all times.
Estimated Running Costs
Benchmarks based on manufacturer documentation (actual costs vary by supplier rates, workflow, and ambient conditions).
| Item | Typical Range | Notes |
|---|---|---|
| Liquid Nitrogen | ≈ 14–15 L per session (≈ 3.7–4.0 gal) | Lower end at higher throughput (>20/day); depends on ambient and session spacing |
| Electricity | Low (controls, fans, interface) | Secondary to LN₂ supply costs |
| Maintenance | Low–Moderate | Follow service intervals and safety checks |
Shipping & Delivery
- Freight (crated) with scheduled delivery window (curbside). This item is not eligible for White Glove.
- Lead times vary by configuration and finish — contact us for the current build schedule.
Need coordinated delivery windows, restricted access planning, or timed installation commissioning? Contact us before checkout.
FAQs
Does this unit expose the head to cold?
Why is a full drying cycle required?
What nitrogen consumption should we plan for?
Is installation included?
What safety requirements should the room have?
Pro Tip: Keep the nitrogen tank as close as practical and minimize hose length—shorter runs help reduce nitrogen loss and support faster pull-down between back-to-back sessions.
Why Buy From Us
Shop trusted wellness brands with authorized dealer support and help choosing the right equipment.
Help understanding coverage and coordinating warranty inquiries. Coverage and registration requirements vary by brand and product.
Personal guidance from My Luxury Home Spa before, during, and after your purchase.
Ordering & Product Support FAQs
Shipping & Delivery
Free standard shipping is available on eligible products and destinations. Large equipment generally ships by freight with curbside delivery unless another service is expressly included.
White-glove placement, assembly, or other upgraded services may be available for select products and locations at an additional cost. Availability, scope, and pricing must be confirmed before booking. Processing, transit, and delivery scheduling vary by product and destination.
Review our Shipping Policy, or contact us before ordering if you need placement assistance or delivery by a particular date.
Warranty
Manufacturer warranty coverage varies by brand, model, component, and intended use. Review the product’s warranty documentation for coverage periods, exclusions, and any registration requirements. Commercial use may have different terms.
For warranty assistance, contact My Luxury Home Spa with your order number, model, serial number, and a description of the issue. We can help coordinate the next steps with the manufacturer or supplier.
Returns
Return eligibility, deadlines, fees, and shipping responsibilities vary by product. Some products have shorter return windows or specific restrictions. Eligible change-of-mind returns generally require unused equipment in its original packaging and written authorization before shipment.
Review our Return & Refund Policy and any product-specific terms before purchasing. Contact us promptly about damaged, defective, or incorrect items; these are reviewed separately from change-of-mind returns.
Installation & Power
Electrical, assembly, foundation, ventilation, drainage, and clearance requirements vary by product. Check the exact model’s specifications and manufacturer instructions before ordering or preparing your space.
Use qualified professionals where required. Delivery or optional placement service does not include electrical wiring, plumbing, site preparation, or full installation unless expressly included in your written service scope. Contact us if you need help locating the appropriate product documentation.